APC Symmetra Lx 16kva N+1 Ext. Run Tower Frame

Redcorp# 02805804 Article# SYAF16KXR9I
€ 8990.18 Excl. VAT
Quantity
-
1
+
Symmetra APC Symmetra Lx 16kva N+1 Ext. Run Tower Frame
For personal help or faster delivery

+32 2 558 30 00

APC Symmetra, 12.8 kW / 16 kVA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, Smart-Slot, Extended runtime model

Includes: CD with software, Documentation CD, Installation guide, User Manual, Web/SNMP Management Card

SYA16K16PXR Features

Shippable with modules installed
Enables pre-installation UPS staging and testing and faster installation.

Removable input/output wiring tray
Allows quick and easy installation and maintenance of the UPS.

Availability:

Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.

Configurable for N+1 internal redundancy
Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

Redundant Intelligence Modules
Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.

Hot-swappable intelligence modules
Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.

Hot-swappable power modules
Ensures clean, uninterrupted power to protected equipment during Power Module replacement.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Power Modules connected in parallel
Enhances availability by allowing immediate, seamless recovery from isolated module failures.

Battery modules connected in parallel
Delivers higher availability through redundant batteries.

Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.

Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.

Scalability:

Scalable power capacity
Reduces UPS over-sizing costs today by allowing quick upgrades later.

Scalable runtime
Allows additional run time to be quickly added as needed.

Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.

Field-replaceable power distribution panel
Ensures compatibility with equipment that has different plug types.

Programmable frequency
Ensures compatibility with different input frequencies.

Manageability:

Manageable external batteries
Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.

Network manageable
Provides remote management of the UPS over the network.

InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.

LCD display
Alpha-Numeric Display which displays system parameters and alarms.

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

SmartSlot
Customize UPS capabilities with management cards.

Serviceability:

Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

User-replaceable intelligence modules
Enables simple upgrades and replacements of the Intelligence Modules.

User-replaceable power modules
Enables simple upgrades and replacements of the Power Modules.

User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Disconnected battery notification
Warns when a battery is not available to provide backup power.

Protection:

Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.

Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.

Generator compatible
Ensures clean, uninterrupted power to the loads in the event of an extended power outage

Cold-start capable
Provides temporary battery power when the utility power is out.

Resettable circuit breakers
Enables a quick recovery from overload events.

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Specs
Features
16 kVA
12800 W
Yes
62 dB
Yes
Ports & interfaces
1
Battery
Sealed Lead Acid (VRLA)
7.5 h
9
Design
Black
Operational conditions
0 - 40 °C
-15 - 45 °C
0 - 95%
0 - 95%
0 - 3000 m
0 - 4500 m
Weight & dimensions
599 mm
997 mm
1880 mm
503.6 kg
535.5 kg
Other features
SYBT5
2PH+N+G
120/208V, 120/240V
AP9619
Smart-Slot
599 x 997 x 1880 mm


Results