APC InRow RC, 600mm, Chilled Water 380-415V 50/60 Hz, with Humidifier

Redcorp# 0280J525 Article# ACRC602P
€ 21729.48 Excl. VAT
Quantity
-
1
+
InRow APC InRow RC, 600mm, Chilled Water 380-415V 50/60 Hz, with Humidifier
For personal help or faster delivery

+32 2 558 30 00

Electric Reheat
Prevents overcooling during dehumidification.

Humidifier
Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure steam canister maintains consistent capacity output, and requires very little or no scheduled maintenance.

InRow Chilled Water CoolingFeatures & Benefits

Manageability

Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.

Real-Time Capacity Monitoring
Real-time display of current and available cooling.

Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.

Total Cost of Ownership

Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.

Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Availability

Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment.

Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.

Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.

Agility

Casters
Provides flexibility to move the unit to wherever cooling is required.

Scaleable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

Modular design
Modular design provides scalable solutions to add cooling as demand increases.

Serviceability

Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Specs
Features
Black
Weight & dimensions
600 mm
1070 mm
1991 mm
352.7 kg
Packaging data
850 mm
1137 mm
2166 mm
463.2 kg


Results