APC NetShelter Rack PDU Advanced Metered Outlet 17.3kW 3PH 415V 30A 530P6 48 Outlet

Redcorp# 0280K956 Article# APDU10350MO
€ 2463.49 Excl. VAT
Starts from € 2395.07 Details
Quantity
-
1
+
NetShelter APC NetShelter Rack PDU Advanced Metered Outlet 17.3kW 3PH 415V 30A 530P6 48 Outlet
For personal help or faster delivery

+32 2 558 30 00

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

Specs
Design
Metered, Metered-by-outlet
Three-phase
Rackmount
0U
Vertical
Black
LCD
Yes
CE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1
Ports & interfaces
48 AC outlet(s)
IEC 60309
C13 coupler, C15 coupler, C19 coupler, C21 coupler
2
1
Features
Yes
Yes
Activity, Network, Power
Yes
Yes
1.8 m
128-bit AES, 192-bit AES, 256-bit AES, DES, MD5, SNMP, SNMPv2, SNMPv3
Yes
Compatible with most NetShelter SX enclosures and third-party racks
Management features
Current, Humidity, Power, Temperature, Voltage
Lock-out, Recycle, Turn off, Turn on
Yes
Network, USB
Power
400 V
50 - 60 Hz
32 A
230 V
22100 VA
3
Overload
22100 W
Weight & dimensions
56 mm
75 mm
1780 mm
9.6 kg
Packaging data
12.6 kg
262 mm
132 mm
1980 mm
Operational conditions
-5 - 60 °C
-25 - 65 °C
5 - 95%
5 - 95%
0 - 3048 m
0 - 15240 m