APC Smart UPS Rt 1500va 1050watts Input:120v/ Output:120v

Redcorp# 02807468 Article# SURTA1500XL
 Search More  UPS
Caractéristiques phares
€ 1662,42 Hors TVA
A partir de € 1616,26 Détails
Quantité
-
1
+
Smart APC Smart UPS Rt 1500va 1050watts Input:120v/ Output:120v
Pour une aide personnalisée ou une livraison plus rapide

+32 2 558 30 00

Includes: CD with software, Documentation CD, Installation guide, Smart UPS signalling RS-232 cable, USB cable, User Manual.

Features

-Automatic internal bypass: Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
-Scalable runtime: Allows additional run time to be quickly added as needed.
-Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
-Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.
-Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power.
-Temperature-compensated battery charging: Prolongs battery life by regulating the charge voltage according to battery temperature.

Manageability
-Network manageable: Provides remote management of the UPS over the network.
-InfraStruXure Manager compatible: Enables centralized management via the APC InfraStruXure® Manager.
-SmartSlot: Customize UPS capabilities with management cards.
-LED status indicators: Quickly understand unit and power status with visual indicators.
-Serial Connectivity: Provides management of the UPS via a serial port.

Adaptability
-Plug-and-Play external batteries: Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
-Rack/Tower convertible: Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
-Flash-upgradeable firmware: Easy implementation of new firmware upgrades.

Serviceability
-User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).
-Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
-Predictive failure notification: Provides early-warning fault analysis ensuring proactive component replacement.
-Disconnected battery notification: Warns when a battery is not available to provide backup power.
-Audible alarms: Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.

Protection
-Frequency and voltage regulation: Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
-Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances.
-Input power factor correction: Minimizes installation costs by enabling the use of smaller generators and cabling.
-Generator compatible: Ensures clean, uninterrupted power to the loads in the event of an extended power outage
-Cold-start capable: Provides temporary battery power when the utility power is out.
-Resettable circuit breakers: Enables a quick recovery from overload events.
-Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.

Specs
Caractéristiques
1,5 kVA
1050 W
50/60 Hz
540 J
45 dB
Batterie
Sealed Lead Acid (VRLA)
8,6 min
22,2 min
3 h
Design
1,83 m
Noir
BSMI,CSA,FCC Part 15 Class B,UL 1778
Conditions environnementales
0 - 40 °C
-20 - 50 °C
0 - 95%
0 - 95%
0 - 3000 m
0 - 15000 m
Poids et dimensions
27,5 kg
Autres caractéristiques
DB-9 RS-232,Smart-Slot,USB
(6) NEMA 5-15R
NEMA 5-15P
85 x 559 x 432 mm
120 V
120 V


Results